Home > Error Unable > Cmdtux_cat 1685

Cmdtux_cat 1685


Simple template. Next step.5. This message is issued to inform the administrator that a redundant boot command has been issued. If it does, retry the desired operation.

ACTION Verify that the environment variable TUXCONFIG is set correctly and exported, or that the TUXCONFIG file is not corrupted (try a tmunloadcf ), or the TUXCONFIG file was propagated to Consult your UNIX system administrator for appropriate actions. 829 ERROR: Error executing `error_cmd' - error DESCRIPTION The user has specified a command error_cmd to be executed if any process fails to If the input is not from a file (for example, from the standard input), then the input is put into a temporary file and this file cannot be opened for reading. ACTION Set and export the TUXCONFIG environment variable and re-execute the command. https://docs.oracle.com/cd/E13203_01/tuxedo/tux71/html/rfcmd24.htm

Error Unable To Open Tuxconfig File

Action Start the tlisten process on the remote machine using the proper NLSADDR value that was specified in the the program again. 1584 ERROR: Unknown error during NLS request to machine Description When sending a message to a tagent But, the database client must be a 32-bit.Let's see.=> Oracle client 64bit librariesHere a test with Peopletools 8.50.02, start process scheduler on W2k8 64bit, and Oracle 64-bit.Booting admin processes ...exec Examples The command generally runs in an interactive mode, and prompts the user for responses to questions when necessary.

exec server-A: Failed. SEE ALSO tmloadcf (1) 879 INFO: A new file system has been created. (size = nblocks size-byte blocks) DESCRIPTION While executing tmloadcf , a new TUXCONFIG file or device was created The following will be about the possible distribution issues.4. Libtux_cat:334: Error: No Bbl Under normal conditions, the BEA Tuxedo system cleans up all allocated IPC resources when it is shut down.

Correct the problem and re-execute the command. Finally, contact your TUXEDO System Technical Support. eDocs Home > BEA Tuxedo 10.0 Documentation > Messages > CMDTUX Catalog List > CMDTUX Messages 1500-1599 CMDTUX Messages 1500-1599 1502 ERROR: Cannot open 'tuxconfig' file Description https://docs.oracle.com/cd/E12531_01/tuxedo100/messages/cdtux/cdtux015.html Server Id = 0 Group Id = ANTLIA Machine = ANTLIA: shutdown succeeded1 process stopped.As expected, that does not start and as usual, first file to check, stderr :LoadLibraryA() in pscompat.dll

Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Verify that the TUXCONFIG file was propagated to all machines in the configuration. Even though the boot process is interrupted (and perhaps aborted by the administrator), the local TUXEDO System process currently being started may succeed or fail. Server.5080.4144.0: LIBTUX_CAT: 607: ERROR: Cannot open section _MACHINES_SECT of the TUXCONFIG: -1 150510.YJL!

Cmdtux_cat 1360

Check the userlog for additional details on this failure. exec TMS-A: process id = 5952 ... Error Unable To Open Tuxconfig File SEE ALSO tmboot (1) 856 ERROR: tmdump failed - can't find BBL DESCRIPTION While attempting to dump the Bulletin Board a system process, the BBL was not available; we cannot join Cmdtux_cat:816: Error: Cannot Exec, Executable File Not Found TUXCONFIG_file Complete path name of the TUXCONFIG file.

Started.Booting server processes ...exec PSMSTPRC -o ./LOGS/stdout -e ./LOGS/stderr -A -- -CD h91tmplt -PS PSUNX -A start -S PSMSTPRC : CMDTUX_CAT:1685: ERROR: Application initialization failuretmboot: CMDTUX_CAT:827: ERROR: Fatal error encountered; initiating Appear open error? See Also malloc(3) in UNIX reference manuals 1575 ERROR: Memory allocation error for TAGENT on machine Description While sending a message to a remote Make sure the TUXCONFIG file is not corrupted (try a tmunloadcf ).

ACTION No action required. No spaces please The Profile Name is already in use Password Notify me of new activity in this group: Real Time Daily Never Keep me informed of the latest: White Papers If the TAGENT on a remote node encounters an error while trying to process the configuration file. ACTION Verify the network listener address in the TUXCONFIG and the address used SEE ALSO tmboot (1) 812 ERROR: Illegal machine id value DESCRIPTION During the tmboot process, the specified servers are booted.

The machine section of the TUXCONFIG file is read and an error has occurred in retrieving this information. SEE ALSO tmboot (1), tmloadcf (1), ubbconfig (5) 809 ERROR: Argument vector formation error DESCRIPTION During the tmboot process, the command line options for a server to be booted is generated. October 11, 2011 3:57 PM Anonymous said... lfmv83 replied Dec 16, 2009 Hi guys, I have a situtation with PeopleTools, while I'm trying to save a Component Interface I get an error about: Tuxedo conversational event ocurred, any